Parameters | 35 reportable parameters: WBC, Neu#, Lym#, Mon#, Eos#, Bas#, IG#, Neu%, Lym%, Mon%, Eos%, Bas%, IG%, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT, MPV, PDW, PCT, P-LCR, P-LCC, IPF, RET#, RET%, LFR, MFR, HFR, IRF, RHE 29 research parameters Two 3D scattergrams & Eight 2D scattergrams & Three histograms |
Principles | CBC+DIFF/RET: Semi-conductor Laser scattering & Fluorescent method & Flow cytometry method WBC/RBC/PLT counting: Impedance method HGB: Cyanide-free colorimetry method |
Reagent | Plasma Diluent-N (20 L); Plasma Diluent-R (1000 mL); Lyse-G (500 mL); Lyse-D (1000 mL); EH 6100 FDN-D (22 mL); EH 6100 FDN-R (12 mL) |
Sample Mode | Venous whole blood, capillary blood |
Repeatability | WBC ≤2.5%(4.0-15.0 x 109/L) RBC ≤1.5%(3.5-6.0 x 1012/L) HGB ≤1.0%(110-180g/L) HCT ≤1.5%(30.0-50.0) MCV ≤1%(70-120fL) PLT ≤4.0%(100-500x 109/L) |
Display | 12.1 inches color screen |
Dimension | 665mm(W)-870mm(H)-820mm(D) |
Throughput | Up to 100 tests per hour |
Sample Volume | CBC: 20ul; CBC+DIFF: 30ul; CBC+DIFF+RET: 35ul (Whole blood) |
Storage | Up to 150,000 records |
Linearity Range | WBC: 0.00-500 x 109/L RBC: 0.00-8.60 x 1012/L HGB: 0-260g/L HCT: 0.0-75.0 % PLT: 0-5000 x 109/L HCT: 0-30.0 % |
Net Weight | 100 kg |
Data Transmission | Bi-directional LIS supported |
Power Requirement | AC 100V ~ 240V (50-60Hz) |
Parameters | 25 reportable parameters: WBC, Neu#, Lym#, Mon#, Eos#, Bas#, Neu%, Lym%, Mon%, Eos%, Bas%, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT, MPV, PDW, PCT, P-LCR, P-LCC 4 research parameters: ALY#, ALY%, LIC#, LIC% 3 histograms for WBC, RBC and PLT One 3D scattergrams and three 2D scattergrams for WBC differention |
Principles | Electrical Impedance method for WBC/BAS count and RBC/PLT tests Cyanide free colorimetry for HGB test Laser-based flow cytometry for WBC differentiation |
Reagent | Plasma Diluent 590 (20 L); Lyse EH 1 (500 mL); Lyse EH 2 (500 mL); Lyse EH 3 (1000 mL) |
Sample Mode | Whole blood, Capillary whole blood and Pre-diluted |
Repeatability | WBC ≤2.0%(4.0-15.0 x 109/L) RBC ≤1.5%(3.5-6.0 x 1012/L) HGB ≤1.5%(110-180g/L) MCV ≤1%(70-120fL) PLT ≤6.0%(100-149x 109/L) ≤4.0%(150-500 x 109/L) |
Dimension | 650mm(W)-550mm(H)-610mm(D) |
Throughput | Up to 90 tests per hour |
Sample Volume | 20 µL |
Storage | Up to 100,000 records |
Linearity Range | WBC: 0.00-300 x 109/L RBC: 0.00-8.50 x 1012/L HGB: 0-250g/L PLT: 0-3000 x 109/L HCT: 0 -67% |
Net Weight | 57.5 kg |
Data Transmission | Support bi-directional LIS |
Power Requirement | 100V ~ 240V, 50/60Hz, ≤ 250VA |
Parameters | 21 reportable parameters: WBC, Gran#, Lym#, Mid#, Gran%, Lym%, Mid%, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT, MPV, PDW, PCT, P-LCR, P-LCC 3 histograms for WBC, RBC and PLT |
Principles | Electrical Impedance method for WBC, RBC and /PLT tests Cyanide free colorimetry for HGB test |
Reagent | Plasma Diluent EH ( 20 L); Stromalyse EH (500 mL) |
Sample Mode | Whole blood ,Capillary blood and Pre-diluted |
Repeatability | WBC ≤2.0%(7.0-15.0 x 109/L) ≤3.5%(4.0-6.9 x 109/L) RBC ≤1.5%(3.50-6.50 x 1012/L) HGB ≤1.5%(100-180g/L) MCV ≤0.5%(70.0-110fL) PLT ≤4.0%(150-500x 109/L) ≤5.0%(100-149 x 109/L) |
Display | 10.4 inches TFT touch screen |
Dimension | 364mm(W)-477mm(H)-417mm(D) |
Throughput | Up to 60 tests per hour |
Sample Volume | 9 µL |
Storage | Up to 50,000 records |
Linearity Range | WBC: 0.00-300 x 109/L RBC: 0.00-8.50 x 1012/L HGB: 0-250g/L PLT: 0-3000 x 109/L HCT: 0.0 -67% |
Net Weight | 26 kg |
Data Transmission | Bi directional LIS with LAN port |
Power Requirement | 100V-240V ~, 50/60Hz |